Prewired conduit with energy cable PLS (RXKX)
MonFlex is a prewired corrugated polypropylene conduit ready to use.
MonFlex, thanks to its innovative technology that eliminates the need for cable insertion into the conduit, offers up to 50% savings during the installation phase, allowing a single installer to independently complete the entire electrical system. Another advantage over traditional methods is the prevention of accidents such as conduit breakage and difficulties in threading cables. MonFlex is suitable for all types of electrical installations, including traditional walls, liquid concrete, concrete, drywall, movable walls, prefabricated structures, and complex systems.
Made entirely of polypropylene, MonFlex is at the forefront compared to the traditional PVC method, ensuring low smoke emissions and the absence of halogen gases, benefiting the environment and people’s health.
Benefits.
Eliminates the threading phase
• Labor cost savings, a single operator needed
• Save time
• Adopts an innovative LSZH (Low Smoke Zero Halogen) technology for safe evacuation.
• Prevent accidents and inconveniences on the construction site
• Ideal for every electrical installation
• Waterproof without micro-holes for liquid concrete
TECHNICAL SPECIFICATIONS
Material
Flexible and self-recovering polypropylene, self-extinguishing,non-flame propagating
Colors
GREY RAL 7035
GREY RAL 7037
GREEN RAL 6018
GREEN RAL 6021
BLACK
BLUE 5012
* Other colors on request
Compression resistance
3422-3342 | 750 Nw
3432 | 1000 Nw
Resistance to impact
3422-3432 | 6J – Heavy
3342 | 2J – Medium
Operating temperature
3422 | *-5° / + 90°
3432 | *-15° / + 90°
3342 | *-25° / + 90°
Standards
LS – LOW SMOKE: IEC 60754-1; IEC 60754-2 ; IEC 10304-1
OH – ZERO HALOGEN: IEC 60754-1; IEC 60754-2 ; IEC 10304-1
FIRE RESISTANCE: EN 61386.1, EN 61386.2
SELF-RECOVERING: EN 61386.1, EN 61386.2
Certifications:
ICTA 34223 / ICTA 33423 / 34323 (1000 Nw)
Applications
Indoor • YES
Outdoor • NO
Exposed installations • NO
Liquid cement and concrete • YES
Chased wall – Plasterboard • YES
Underfloor • YES
False ceiling– Movable wall • YES
Prefab – Wood panels • YES
CABLE THECNICAL SPECIFICATION
Type: PLS (RXKX)
CPR: Eca
Conductor: red copper, flexible formation, class 5
Isulation: Special PVC
Color insulation: Grey RAL 7035
Colors conduit:
Blue – Brown
Functional feautures
Rated voltage: 450/750 V
Operating temperature: -10° / +70°
Installation condition:
• Minimum installation temperature: 5°C
• Reccommended minimum bending radius: 6 times the cable diameter
• Recommended maximum tensile stress: 50 N/mm2 of the cross-section of the copper.
For fixed laying in above-ground or built-in pipes or in similar closed systems. Cable suitable for protected installation in lighting and control appliances for voltage up to 1000 V in a.c. or up to 750 V in d.c. landward. Contact with water is not permitted.
Reference Construction Products Regulation 305/2011 EU and Standard EN 50575: The cable is suitable for the supply of electricity in buildings and other civil engineering works.
FORMATION
CONDUIT: Ø 16
2×1,5
CONDUIT: Ø 20
2×1,5
CONDUIT: Ø 25
2×1,5
PACKAGING
STANDARD (25 / 50 / 100 Mt)
ROLLS
Ø 16
Roll 25 Mt – Pallet 1575
Roll 50 Mt – Pallet 3150
Roll 100 Mt – Pallet 2800
Ø 20
Roll 25 Mt – Pallet 2250
Roll 50 Mt – Pallet 2100
Roll 100 Mt – Pallet 2400
Ø 25
Roll 25 Mt – Pallet 1125
Roll 50 Mt – Pallet 1575
Roll 100 Mt – Pallet 2000
WOODEN REELS
(250 / 300 Mt)
Ø 16
Reel 250 Mt – Pallet 3000
Reel 300 Mt – Pallet 3600
Ø 20
Reel 250 Mt – Pallet 2000
Reel 300 Mt – Pallet 2400
Ø 25
Reel 300 Mt – Pallet 600
BIG ROLLS
Ø 16
Up to 1000 Mt
Ø 20
Up to 900 Mt
Ø 25
Up to 600 Mt